GrundigGSC100Dead - blowing 3.15 fuse - intermittently.EHT cap arcing.14-09-04
GrundigGSC100Dead - blowing 3.15amp fuse.EHT cap jumping across to degaussing coil.14-09-04

GrundigGSC100Dead.R607 o/c , faulty thyristors , insulation in line o/p stage.14-09-04
GrundigGSC100Dead.Di511 or C2502 ( 100u f , 16v ) on EHT control regel baust PCB.14-09-04
GrundigGSC100Frame - bottom foldover - cramping at top.R2522 ( 2.2k ) goes high.14-09-04
GrundigGSC100IF EHT IS VERY HIGHCHECK DI508 IS OPEN14-09-04
GrundigGSC100Line break up.C2502 ( 100uf , 16v ) on EHT control regel baust PCB.14-09-04
GrundigGSC100No frame.Di447 ( 1N4007 ) and/or TDA1170.14-09-04
GrundigGSC100R607 - repeated resoldering of R607.Di2502 ( 4.7v ) zener.14-09-04